Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Magn Reson Imaging ; 39(1): 189-94, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24123420

RESUMO

PURPOSE: To evaluate image quality when using a CAIPIRINHA sampling pattern in comparison to a standard GRAPPA sampling pattern in patients undergoing a routine three-dimensional (3D) breathheld liver exam. CAIPIRINHA uses an optimized phase encoding sampling strategy to alter aliasing artifacts in 3D acquisitions to improve parallel imaging reconstruction. MATERIALS AND METHODS: Twenty patient volunteers were scanned using a 3D VIBE acquisition with an acceleration factor of four using a CAIPIRINHA and standard GRAPPA sampling pattern. CAIPIRINHA and GRAPPA images were evaluated by three radiologists in a two alternative forced choice test, and the Wilcoxon signed rank test was performed. RESULTS: The CAIPIRINHA sampling pattern was preferred in an average of 68% of the comparisons, and the Wilcoxon signed rank test showed a significant improvement in CAIPIRINHA images (P = 0.014). This analysis indicates that in the given sample set, CAIPIRINHA preference over the GRAPPA standard was statistically significant. CONCLUSION: This work shows that for an acceleration factor of four, a CAIPIRINHA accelerated VIBE acquisition provides significantly improved image quality in comparison to the current GRAPPA standard. This allows a further reduction in imaging time for similar spatial resolutions, which can reduce long breathhold requirements in abdominal imaging, and may be particularly helpful in patients who cannot provide requisite breathholds with current protocols.


Assuntos
Abdome/patologia , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Suspensão da Respiração , Meios de Contraste/química , Humanos , Imageamento Tridimensional/normas , Fígado/patologia , Imageamento por Ressonância Magnética/normas , Pessoa de Meia-Idade , Variações Dependentes do Observador , Software , Fatores de Tempo , Adulto Jovem
2.
J Magn Reson Imaging ; 38(5): 1237-44, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23389970

RESUMO

PURPOSE: To obtain a simultaneous 3D magnetic resonance angiography and perfusion (MRAP) using a single acquisition and to demonstrate MRAP in the lower extremities. A time-resolved contrast-enhanced exam was used in MRAP to simultaneously acquire a contrast-enhanced MR angiography (MRA) and dynamic contrast-enhanced (DCE) perfusion, which currently requires separate acquisitions and thus two contrast doses. MRAP can be used to assess large and small vessels in vascular pathologies such as peripheral arterial disease. MATERIALS AND METHODS: MRAP was performed on 10 volunteers following unilateral plantar flexion exercise (one leg exercised and one rested) on two separate days. Data were acquired after administration of a single dose of contrast agent using an optimized sampling strategy, parallel imaging, and partial-Fourier acquisition to obtain a high spatial resolution, 3D-MRAP frame every 4 seconds. Two radiologists assessed MRAs for image quality, a signal-to-noise ratio (SNR) analysis was performed, and pharmacokinetic modeling yielded perfusion (K(trans) ). RESULTS: MRA images had high SNR and radiologist-assessed diagnostic quality. Mean K(trans) ± standard error were 0.136 ± 0.009, 0.146 ± 0.012, and 0.191 ± 0.012 min(-1) in the resting tibialis anterior, gastrocnemius, and soleus, respectively, which significantly increased with exercise to 0.291 ± 0.018, 0.270 ± 0.019, and 0.338 ± 0.022 min(-1) . Bland-Altman analysis showed good repeatability. CONCLUSION: MRAP provides simultaneous high-resolution MRA and quantitative DCE exams to assess large and small vessels with a single contrast dose. Application in skeletal muscle shows quantitative, repeatable perfusion measurements, and the ability to measure physiological differences.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Extremidade Inferior/fisiologia , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Músculo Esquelético/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Músculo Esquelético/irrigação sanguínea , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Am J Physiol Endocrinol Metab ; 301(3): E511-6, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21712533

RESUMO

The relationship between intramyocellular (IMCL) and extramyocellular lipid (EMCL) accumulation and skeletal muscle insulin resistance is complex and dynamic. We examined the effect of a short-term (7-day) low-glycemic index (LGI) diet and aerobic exercise training intervention (EX) on IMCL and insulin sensitivity in older, insulin-resistant humans. Participants (66 ± 1 yr, BMI 33 ± 1 kg/m(2)) were randomly assigned to a parallel, controlled feeding trial [either an LGI (LGI/EX, n = 7) or high GI (HGI/EX, n = 8) eucaloric diet] combined with supervised exercise (60 min/day, 85% HR(max)). Insulin sensitivity was determined via 40 mU·m(-2)·min(-1) hyperinsulinemic euglycemic clamp and soleus IMCL and EMCL content was assessed by (1)H-MR spectroscopy with correction for fiber orientation. BMI decreased (kg/m(2) -0.6 ± 0.2, LGI/EX; -0.7 ± 0.2, HGI/EX P < 0.0004) after both interventions with no interaction effect of diet composition. Clamp-derived insulin sensitivity increased by 0.91 ± 0.21 (LGI/EX) and 0.17 ± 0.55 mg·kg(-1)·min(-1) (HGI/EX), P = 0.04 (effect of time). HOMA-IR was reduced by -1.1 ± 0.4 (LGI/EX) and -0.1 ± 0.2 (HGI/EX), P = 0.007 (effect of time), P = 0.02 (time × trial). Although both interventions increased IMCL content, (Δ: 2.3 ± 1.3, LGI/EX; 1.4 ± 0.9, HGI/EX, P = 0.03), diet composition did not significantly effect the increase. However, the LGI/EX group showed a robust increase in the [IMCL]/[EMCL] ratio compared with the HGI/EX group (Δ: 0.5 ± 0.2 LGI/EX vs. 0.07 ± 0.1, P = 0.03). The LGI/EX group also demonstrated greater reductions in [EMCL] than the HGI/EX group (Δ: -5.8 ± 3.4, LGI/EX; 2.3 ± 1.1, HGI/EX, P = 0.03). Changes in muscle lipids and insulin sensitivity were not correlated; however, the change in [IMCL]/[EMCL] was negatively associated with the change in FPI (r = -0.78, P = 0.002) and HOMA-IR (r = -0.61, P = 0.03). These data suggest that increases in the IMCL pool following a low glycemic diet and exercise intervention may represent lipid repartitioning from EMCL. The lower systemic glucose levels that prevail while eating a low glycemic diet may promote redistribution of lipid stores in the muscle.


Assuntos
Dieta , Exercício Físico/fisiologia , Índice Glicêmico/fisiologia , Resistência à Insulina/fisiologia , Insulina/metabolismo , Obesidade/terapia , Idoso , Envelhecimento/fisiologia , Glicemia/metabolismo , Composição Corporal , Terapia por Exercício , Feminino , Humanos , Estilo de Vida , Peroxidação de Lipídeos/fisiologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Obesidade/metabolismo , Obesidade/fisiopatologia , Resultado do Tratamento
4.
AJR Am J Roentgenol ; 195(4): 858-64, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20858810

RESUMO

OBJECTIVE: The goal of this study was to compare time-resolved MR angiography (MRA) and bolus-chase MRA in the identification of peroneal artery septocutaneous perforators and for classification of the branching pattern of the arterial tree in the leg in a cohort of candidates for fibular free flap transfer operations. MATERIALS AND METHODS: Retrospective analysis was performed on imaging data from 53 legs of 27 patients (age range, 27-88 years) who underwent time-resolved MRA (FLASH; TR/TE, 2.5/1.0; flip angle, 22°; voxel dimensions, 1.54 × 1.25 × 1.5 mm; acquisition time, 2.27 s/frame) and bolus-chase MRA (FLASH; 3.2/1.2; flip angle, 25°; voxel dimensions, 0.94 × 0.89 × 1 mm) at 3 T with gadobenate dimeglumine administered at 0.05 and 0.10 mmol/kg, respectively. The branching pattern was analyzed; the total number of septocutaneous perforators for each leg was calculated from the time-resolved and bolus-chase MRA data; and the results were combined. The total and average number of septocutaneous perforators per leg and the frequency of various branching patterns were calculated. The techniques were compared in terms of branching pattern and number of visible septocutaneous perforators. RESULTS: A total of 84 septocutaneous perforators (1.58 ± 1.05 [SD] per leg) were identified. Pattern 1A was found in 42 legs; 1B, two legs; 2A, one leg; 2B, one; 3A, four; 3B, one; and 3D, two legs. Classification with time-resolved MRA was successful for 53 legs and with boluschase MRA for 51 legs (Z = 0.713, p = 0.24, one-tailed, not significant). Twenty-two septocutaneous perforators were identified with time-resolved MRA and 82 with bolus-chase MRA. CONCLUSION: MRA of the leg can be used to investigate the branching pattern and identify septocutaneous perforators in a single step. With the imaging parameters and contrast dose used in this study, septocutaneous perforators can be better identified with boluschase MRA, although this result may be partially related to the higher gadolinium dose used in this technique.


Assuntos
Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
5.
Clin Cancer Res ; 13(19): 5862-8, 2007 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-17908980

RESUMO

PURPOSE: We used inflammatory breast cancer (IBC) as a model disease to investigate biological changes associated with an antiangiogenesis agent, SU5416, combined with doxorubicin. EXPERIMENTAL DESIGN: Patients with stage IIIB or IV IBC were treated neoadjuvantly with the combination of SU5416 and doxorubicin for induction therapy. The dose of SU5416 (administered on days 1 and 4, every 3 weeks) and doxorubicin (administered on day 1 every 3 weeks) were escalated in cohorts of three patients starting at 110 and 60 mg/m2, respectively, for a total of five cycles leading up to mastectomy. Patients underwent serial assessment (pharmacokinetic sampling, biopsy of breast, tumor blood flow dynamic contrast-enhanced magnetic resonance imaging, plasma angiogenesis, and endothelial cell damage markers) prior to treatment, at the end of cycles no. 2 and no. 5, and after mastectomy. RESULTS: Eighteen patients were enrolled; neutropenia was dose-limiting, and overall median survival was not reached (50 months of study follow-up). Four patients (22%) experienced congestive heart failure, which resolved and were likely attributable to a smaller volume of distribution and higher Cmax of doxorubicin in combination with SU5416. We did observe a significant decline in tumor blood flow using Kep calculated by Brix (pretreatment versus post-cycle no. 5; P = 0.033), trend for a decline in tumor microvessel density after treatment, and low baseline levels of soluble intracellular adhesion molecule were associated with improved event-free survival. CONCLUSIONS: This study showed evidence of an unfavorable cardiac interaction between SU5416 and doxorubicin, which prohibits further investigation of this combination. However, this study supports the importance of using IBC as a model for investigating angiogenesis inhibitors.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Doxorrubicina/administração & dosagem , Indóis/administração & dosagem , Neovascularização Patológica/patologia , Pirróis/administração & dosagem , Adulto , Idoso , Inibidores da Angiogênese/farmacologia , Intervalo Livre de Doença , Feminino , Humanos , Inflamação , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Resultado do Tratamento
6.
J Magn Reson Imaging ; 24(3): 586-94, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16892197

RESUMO

PURPOSE: To quantify the unknown relative sensitivities of semiquantitative measures from dynamic contrast-enhanced (DCE) MRI to variations in the volume fraction V(e) of the extravascular extracellular space (EES), and the duration of the contrast injection. MATERIALS AND METHODS: Tissue-uptake curves were simulated across various values of F, PS, V(e), and bolus timings, with and without additive noise and at different image reacquisition rates. From each, the peak of the first derivative (G(peak)), the total uptake after the rapid first phase (CE), and the IAUC were calculated and plotted against F for each experimental condition. Relationships between each measure and the corresponding quantitative measure K(trans) were also examined, particularly for linearity. RESULTS: The highest sensitivity to flow was achieved for shorter bolus timings for G(peak), CE, and IAUC. G(peak) and IAUC were most linearly related to K(trans). The sensitivity to V(e) was lowest for G(peak), followed by IAUC and CE. Long sampling intervals resulted in severe underestimation of G(peak), while IAUC was unaffected provided that the limits of integration were properly applied. G(peak) could not be properly calculated in the presence of noise without a prior smoothing of the acquired curves, while IAUC was again unaffected by noise. CONCLUSION: G(peak) and IAUC are both useful model-free analogs of blood flow (i.e., K(trans)) for pre- and posttreatment comparisons. G(peak) may be the better choice in cases where larger changes in V(e) are likely, but only if sufficient noise reduction and fast image sampling are applied. If V(e) is expected to remain stable, IAUC is superior to G(peak) by virtue of its stability in the face of noise and more reliable estimation over a wider range of sampling rates.


Assuntos
Meios de Contraste/administração & dosagem , Meios de Contraste/farmacologia , Imageamento por Ressonância Magnética/métodos , Espaço Extracelular/metabolismo , Gadolínio DTPA/farmacologia , Humanos , Modelos Estatísticos , Neovascularização Patológica , Sensibilidade e Especificidade , Fatores de Tempo , Distribuição Tecidual
7.
Radiology ; 238(2): 497-504, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16436814

RESUMO

PURPOSE: To evaluate an augmented reality (AR) system in combination with a 1.5-T closed-bore magnetic resonance (MR) imager as a navigation tool for needle biopsies. MATERIALS AND METHODS: The experimental protocol had institutional animal care and use committee approval. Seventy biopsies were performed in phantoms by using 20 tube targets, each with a diameter of 6 mm, and 50 virtual targets. The position of the needle tip in AR and MR space was compared in multiple imaging planes, and virtual and real needle tip localization errors were calculated. Ten AR-guided biopsies were performed in three pigs, and the duration of each procedure was determined. After successful puncture, the distance to the target was measured on MR images. The confidence limits for the achieved in-plane hit rate and for lateral deviation were calculated. A repeated measures analysis of variance was used to determine whether the placement error in a particular dimension (x, y, or z) differed from the others. RESULTS: For the 50 virtual targets, a mean error of 1.1 mm +/- 0.5 (standard deviation) was calculated. A repeated measures analysis of variance indicated no statistically significant difference (P > .99) in the errors in any particular orientation. For the real targets, all punctures were inside the 6-mm-diameter tube in the transverse plane. The needle depth was within the target plane in 11 biopsy procedures; the mean distance to the center of the target was 2.55 mm (95% confidence interval: 1.77 mm, 3.34 mm). For nine biopsy procedures, the needle tip was outside the target plane, with a mean distance to the edge of the target plane of 1.5 mm (range, 0.07-3.46 mm). In the animal experiments, the puncture was successful in all 10 cases, with a mean target-needle distance of 9.6 mm +/- 4.85. The average procedure time was 18 minutes per puncture. CONCLUSION: Biopsy procedures performed with a combination of a closed-bore MR system and an AR system are feasible and accurate.


Assuntos
Biópsia por Agulha/métodos , Imageamento por Ressonância Magnética , Animais , Modelos Animais , Suínos
8.
J Magn Reson Imaging ; 23(2): 135-44, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16416441

RESUMO

PURPOSE: To assess magnetic resonance (MR) pulse sequences for high resolution intravascular imaging. MATERIALS AND METHODS: Intravascular imaging of the abdominal aorta and iliac arteries was performed in vivo in a porcine model at 1.5 T using catheter-mounted micro-receive coils. Ten protocols, including spin-echo (SE)-echo planar imaging (SE-EPI), segmented EPI, half-Fourier single-shot turbo spin-echo (HASTE), fast imaging with steady-state free precession (TrueFISP), turbo spin-echo (TSE), and SE acquisition schemes were employed in 13 trials. Images were analyzed by six expert raters with respect to wall-conspicuity, wall-to-lumen/tissue contrast, visible layers of the arterial wall, anticipated clinical usefulness, and overall image quality. Mean differences between sequence-types were evaluated using analysis of variance (ANOVA) between groups with planned comparisons. RESULTS: The vessel wall was delineated in almost all protocols. Motion artifacts from physiological and device motion were reduced in fast techniques. The best contrast between the wall and surrounding tissue was provided by a HASTE protocol. Anatomic layers of the vessel wall were best depicted on dark blood T2-weighted TSE. Overall, TrueFISP was ranked highest on the remaining measures. CONCLUSION: Dedicated catheter-coils combined with fast sequences have potential for in vivo characterization of vessel walls. TrueFISP offered the best overall image quality and acquisition speed, but suffered from the inability to delineate the multiple layers of the wall, which seems associated with dark blood- and T2-weighted contrast. We believe future intra-arterial trials should proceed from this study in normal artery imaging and initially focus on fast T2-weighted dark blood techniques in trials with pathology.


Assuntos
Aorta Abdominal/anatomia & histologia , Imagem Ecoplanar/métodos , Artéria Ilíaca/anatomia & histologia , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Análise de Variância , Animais , Cateterismo , Endotélio Vascular/anatomia & histologia , Desenho de Equipamento , Análise de Fourier , Angiografia por Ressonância Magnética/instrumentação , Modelos Animais , Sensibilidade e Especificidade , Suínos , Ultrassonografia de Intervenção
9.
J Magn Reson Imaging ; 18(5): 575-84, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14579401

RESUMO

PURPOSE: To examine the sensitivity of quantitative dynamic contrast enhanced MRI (DCE-MRI) perfusion maps to errors in the various source images and to determine optimal imaging parameters for reducing this sensitivity. MATERIALS AND METHODS: A detailed analysis of the precision of a DCE-MRI protocol was performed using the "propagation of errors" technique to investigate the effect of errors in the source images on errors in K(trans). Optimal parameter values and interactions between parameters were examined. The propagation of errors analysis was validated by Monte-Carlo simulations. RESULTS: The precision of K(trans) was found to be most sensitive to artifacts in the tissue portion of the baseline images and least sensitive to noise in the arterial portion of the dynamic images. The tip-angle strongly affected the precision, with the optimum being a function of tissue T1(0). CONCLUSION: Protocol optimization requires matching the tip-angle to the anticipated T1(0) of the tissue of interest; however such optimization yields a relatively small improvement. Future developmental efforts would be most productively focused on minimizing the artifact level.


Assuntos
Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste , Humanos , Modelos Cardiovasculares , Método de Monte Carlo , Perfusão
10.
Schizophr Res ; 55(1-2): 99-104, 2002 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-11955969

RESUMO

There is a small but intriguing body of literature which suggests that head size may be reduced in patients with schizophrenia. This literature sits alongside more substantial and compelling evidence that there is a reduction in cerebral volume in schizophrenia. As an extension of earlier work, measures of extracranial head size derived from standard anthropometric approaches were assessed in 44 patients and 46 control subjects. Head size was found to be normal in schizophrenia. The relationship of brain size to head size is elaborated.


Assuntos
Cefalometria , Esquizofrenia/diagnóstico , Adulto , Encéfalo/patologia , Feminino , Hospitais Psiquiátricos , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Valores de Referência
11.
Psychiatry Res ; 114(1): 51-6, 2002 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-11864809

RESUMO

Several reports have noted an increase in white matter hyperintensities (WMH) on MRI scans of adult patients with bipolar disorder. We investigated whether this increase was also evident in a group of adolescent patients with bipolar disorder. The sample consisted of 15 bipolar patients, 19 patients with schizophrenia and 16 healthy comparison subjects. All subjects were adolescents. WMH were blindly rated on T2-weighted and PD-weighted MRI scans using our own scale with documented inter-rater reliability. WMH were present in 10 of 15 bipolar patients (67%), seven of 19 patients with schizophrenia (37%) and five of 16 comparison subjects (31%). The bipolar adolescent group had a statistically significant increased presence of WMH compared both with healthy comparison subjects and the schizophrenic group. The association between WMH and bipolar disorder appears to extend to the adolescent years.


Assuntos
Transtorno Bipolar/diagnóstico , Encéfalo/patologia , Imageamento por Ressonância Magnética , Adolescente , Dano Encefálico Crônico/diagnóstico , Mapeamento Encefálico , Criança , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valores de Referência , Esquizofrenia/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...